1.0 Introduction
4 1
STANDARD
B.S. 6891
B.S. 5546
B.S. 5449
B.S. 6798
B.S. 5440: Pt 1
B.S. 5440: Pt 2
SCOPE
Gas Installation.
Installation of hot water supplies for
domestic purposes.
Forced circulation hot water systems.
Installation of gas fired hot water
boilers.
Flues.
Ventilation.
HEAT OUTPUT
Model Min Max
30 5.86kW (20,000 Btu/h) 8.79kW (30,000 Btu/h)
40 9.09kW (31,000 Btu/h) 11.72kW (40,000 Btu/h)
50 12.02kW (41,000 Btu/h) 14.65kW (50,000 Btu/h)
60 14.95kW (51,000 Btu/h) 17.58kW (60,000 Btu/h)
70 17.88kW (61,000 Btu/h) 20.5kW (70,000 Btu/h)
80 20.8kW (71,000 Btu/h) 23.45kW (80,000 Btu/h)
B.S. Codes of Practice
1.1 Description
1. The Baxi Solo 2 PF is a gas fired room sealed
fan assisted central heating boiler with range rated
outputs as shown in the table below
2. Each appliance is preset at a MID
RANGE heat
input rating and is designed for use on NATURAL
GAS only.
3. All boilers are suitable for fully pumped open
vented central heating and domestic hot water
systems and sealed systems.
4. The appliance data badge is fitted to the
combustion box door.
1.2 Installation
1. The appliance is suitable for installation only in
G.B. and I.E. and should be installed in
accordance with the rules in force. For Ireland
install in accordance with I.S.813 “I
NSTALLATION OF
GAS APPLIANCES. The installation must be carried
out by a CORGI Registered Installer or other
competent person and be in accordance with the
relevant requirements of G
AS SAFETY (Installation
and Use) R
EGULATIONS, the BUILDING REGULATIONS
(Scotland) (Consolidation), the LOCAL BUILDING
REGULATIONS, the CURRENT I.E.E. WIRING
REGULATIONS and the bye laws of the Local Water
Undertaking. Where no specific instructions are
given, reference should be made to the relevant
BRITISH STANDARD CODES OF PRACTICE.
2. All systems must be thoroughly flushed and
treated with inhibitor (see Section 3.1).
1.3 Important Information
This product contains Refractory Ceramic Fibres
(R.C.F.) which are man-made vitreous silicate
fibres. Excessive exposure to these materials may
cause tempory irritation to eyes, skin and
respiratory tract. Care must be taken when
handling these articles to ensure the release of
dust or fibres is kept to a minimum.
To ensure that the release of fibres from these
articles is kept to a minimum, during installation
and servicing it is recommended that a H.E.P.A.
filtered vacuum is used to remove any dust, soot
or other debris accumulated in and around the
appliance. This should be performed before and
after working on the installation.
It is recommended that any replaced item(s) are
not broken up but sealed within heavy duty
polythene bags and clearly labelled “R.C.F.
waste”. This is not classified as “hazardous waste”
and may be disposed of at a tipping site licensed
for the disposal of industrial waste.
Protective clothing is not required when handling
these articles but it is recommended that gloves
are worn and the normal hygiene rules of not
smoking, eating or drinking in the work area are
followed and always wash hand
s before eating or
drinking.