2.0 Technical Data
1 5
Model 30 40 50 60 70 80
Heat Output (Max) kW 8.9 11.72 14.65 17.58 20.5 23.45
Btu/h 30,000 40,000 50,000 60,000 70,000 80,000
Heat Output (Min) kW 5.86 9.09 12.02 14.95 17.88 20.8
Btu/h 20,000 31,000 41,000 51,000 61,000 71,000
Heat Input (Max) kW 10.99 14.65 18.32 21.98 25.64 29.31
Btu/h 37,500 50,000 62,500 75,000 87,500 100,000
Heat Input (Min) kW 7.33 11.36 15.02 18.68 22.35 26.01
Btu/h 25,000 38,750 51,250 63,750 76,250 88,750
Burner Pressure (Max) mbar 16.0 ±0.5 16.0 ±0.5 16.0 ±0.5 16.0 ±0.5 16.0 ±0.5 16.0 ±0.5
in wg 6.4 ±0.2 6.4 ±0.2 6.4 ±0.2 6.4 ±0.2 6.4 ±0.2 6.4 ±0.2
Burner Pressure (Min) mbar 8.0 ±0.5 10.0 ±0.5 11.5 ±0.5 11.5 ±0.5 12.1 ±0.5 11.5 ±0.5
in wg 3.2 ±0.2 4.0 ±0.2 4.4 ±0.2 4.4 ±0.2 4.8 ±0.2 4.4 ±0.2
Gas Rate CV 38MJm
3
1.04m
3
/h 1.39m
3
/h 1.74m
3
/h 2.08m
3
/h 2.78m
3
/h 2.78m
3
/h
(after 10 mins) 36.86ft
3
/h 49.0ft
3
/h 61.3ft
3
/h 73.5ft
3
/h 98.1ft
3
/h 98.1ft
3
/h
Lifting Weight kg 23.1 23.1 23.1 32.2 32.2 34.2
lbs 51 51 51 71 71 75.5
Water Content litres 1.1 1.1 1.1 1.6 1.6 1.3
pints 1.9 1.9 1.9 2.8 2.8 2.3
Outercase Height 600mm 600mm 600mm 600mm 600mm 600mm
Dimensions Width 350mm 350mm 350mm 462mm 462mm 462mm
Depth 287mm 287mm 287mm 287mm 287mm 287mm
Flue Terminal Diameter 100mm
Dimensions Depth 65mm
Static Head Max 30 metres (100 ft)
Min 1 metres (3.25 ft)
Connections Flow 22mm Cu tail
Return 22mm Cu elbow
Heat Exchanger Cast iron monobloc
Low Head Min 0.2m (8 in)
System Design fully pumped open vented and sealed systems
Gas Connection RC
1
/
2
(
1
/
2
in BSPT)
Electrical Supply 230V ~ 50Hz fused 5A - 90W
Controls boiler thermostat, pilot & electronic flame sensing, timed pump over-run,
frost protection thermostat
Internal Fuse 4AF 250V to BS4256 situated on control board