4.0 Site Requirements
11
4.3 Flue Position (Cont)
WARNING - The addition of anything that may
interfere with the normal operation of the
appliance (e.g. FLUE DAMPERS,
ECONOMISERS,etc.) without the express
written permission of Baxi Heating Ltd could
invalidate the appliance warranty and infringe
the GAS SAFETY (Installation and Use)
REGULATIONS.
If a terminal is less than 2 metres (78
3
/
4
in)
above a balcony, above ground or above a flat
roof to which people have access then a
suitable terminal guard must be provided.
6. Table 2 and the accompanying diagram show
the positioning of the flue terminal relative to
buildings and other structures.
7. The dimensions of the flue terminal are shown
in Fig. 12.
4.4 Flue Dimensions
1. The standard flue supplied with the appliance
is suitable for use with flue lengths between
100mm (4in) and 685mm (27in).
NOTE: Maximum flue length when flued to the
left or right is
584mm (23in) - 30, 40, 50 PF
533mm (21in) - 60, 70, 80 PF
2. Flue extension kits are available as an optional
extra for installations up to 1 metre
(39
3
/
8
in) and up to 2 metres (79
3
/
4
in). 2 metre kit
is not available for the 70 and 80 PF model.
3. A vertical flue kit, with flue breaker, is also
available as an optional extra (Sol-Ver Kit).
4. Where it is intended to pass the flue through a
combustible wall or timber framed dwelling,
reference should be made to British Gas
publication DM2.
5. If the flue is more than 1.8 metres (70
7
/
8
in)
long, it is required that it is supported.
6. All above dimensions are taken from the
respective faces of of the outer case.
D
A
F
F
G
B,C
A
G
E
G
J
K
D
L
H,I
Likely positions requiring
a flue terminal guard
65
100
Table. 2
Fig. 12
Flue Terminal Dimensions
Terminal Position with Minimum Distance (mm)
A Directly below an openable window or other
opening, e.g. an air brick. 300
B Below gutters. 25
C Below eaves, soil pipes or drain pipes. 75
D Below balconies or car port roof 200
E From vertical drain pipes and soil pipes. 75
F From internal or external corners. 25
G Above ground, roof or balcony level. 300
H From a surface facing a terminal. 600
I From a terminal facing a terminal. 1200
J Vertically from a terminal on the same wall. 1500
K Horizontally from a terminal on the same wall. 300
L For an opening in a car port (e.g. door, window)
into a dwelling. 1200