9.0 Annual Servicing
36
9.2 Cleaning the Combustion Box
1. Remove the burner assembly by pulling it
forward (Fig. 94).
2. Lightly brush any dirt from the top of the burner
blades and ensure that the ports are free from
obstruction.
3. Lift the baffles out of the heat exchanger, using
the corner tabs on 30,40,50,60,70 models
(Fig. 94).
9.3
Cleaning the Heat Exchanger
1. The heat exchanger may be cleaned by
insertion of a thin metal strip e.g. a hack saw
blade or steel rule, from above or below, taking
care not to damage any insulation.
2. Clean the front and rear fin sections and
ensure that any blockages are cleared.
9.4
Cleaning the Burner Injector
1. Remove the injector which is screwed into the
burner feed manifold (Fig. 95).
2. Examine and clean carefully, then replace
ensuring that the copper washer is in position.
Tighten the injector fully.
9.5 Cleaning the Pilot
1. Disconnect the spark electrode lead at the
electrode (Fig. 96).
2. Unscrew the electrode from the manifold and
withdraw the electrode (Fig. 96).
3. Remove the right hand side insulation carrier
bracket by releasing the screw. Remove the side
insulation (Fig. 94).
4. Release the screw securing the pilot hood and
remove (Fig. 96a).
5. Carefully remove the pilot injector (Fig. 96a).
Examine and clean it as necessary. Do not use a
wire or pin to clean the injector orifice.
6. Examine the sealing washer (Fig. 96a) and
replace if it is damaged in any way. Reassemble
in reverse order.
7. Replace all components in reverse order, (On
30,40,50,60,70 models refit the rear baffle by
holding it at an angle and locating the lower
fingers between the heat exchanger and rear
insulation. Lower it into position as shown)
(Fig. 97).
8. Check that the seal to the combustion box door
is good.
9. Re-commission the boiler before use, checking
for gas soundness and ensuring all controls are
working correctly.
60, 70 & 80 PF
Models Only
Fig. 94
Fig. 95
Fig. 97
Fig. 96
Fig.96a
Pilot Hood
Pilot Injector
Sealing Washer
Electrode
Baffles -
80 models only
Baffle -
30, 40, 50, 60, 70 models
Baffles - 30, 40, 50, 60, 70 models
Page view 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 42 43 44

Comments to this Manuals

No comments