14.0 Fault Finding
40
Check and correct if necessary
1. Electrical and pressure tube connections
2. Blockage of pressure tubes
3. Restriction in flue
4. Venturi
NO
E
Replace air
pressure switch
Gas at burner
Ensure gas is on and purged
Replace PCB
Replace gas valve
neon illuminated
PCB - M4 connector is approx 70-140V DC,
terminals 23 & 24
YES
Turn selector switch
to reset position
R
YES
NO
NO
NO
F
Replace PCB
G
Check and correct if necessary
1. Ignition electrode and lead
2. Electrode connection
3. Spark gap and position
230V at Main PCB - M4
connector across terminals
25 & 26 and at igniter.
Check wiring
YES
NO
Replace igniter
YES
H
YES
Check the burner setting pressure of
the gas valve
(see Section 9.2 of Commissioning)
1.
Voltage at main PCB - M4 connector is:
approx 70 - 140V DC across terminals 23 & 24
approx 20 - 70V DC across terminals 21 & 22
Min burner pressure approx 14 mA DC across
terminals 21 & 22
Max burner pressure approx 35 mA DC across
terminals 21 & 22
Replace gas valve
NO
Replace PCB
2.