16 EcoBlue Plus Combi 7212136 - 02 (08/14)
3 Technical Specifications
0
200 400 600 800 1000 1200
0.5
1
1.5
2
2.5
3
3.5
4
Metre (wg)
Flow Rate (l/h)
Pump - Available Head
0
5
5.5
6
4.5
Pump
Available Head See graph below
Dynamic (nominal) Inlet Pressure
(Natural Gas - G20)
mbar 20
with a CV of 37.78 MJ/m
3
Max Gas Rate (Natural Gas - G20)
(After 10 mins)
24 model m
3
/h 2.61
28 model m
3
/h 3.05
33 model m
3
/h 3.59
NATURAL GAS ONLY !
SAP 2005 Seasonal Efficiency is
91.1%
SAP 2009 Annual Efficiency is
89%
This value is used in the UK Government’s
Standard Assessment Procedure (SAP) for energy
rating of dwellings. The test data from which it has
been calculated has been certified by 0085.
SEDBUK Declaration
NOTE: All data in this section are nominal
values and subject to normal production
tolerances.
3.1 Technical Data (cont)