Baxi EcoBlue Plus Combi Quick Start Manual Page 1

Browse online or download Quick Start Manual for Water heaters & boilers Baxi EcoBlue Plus Combi. Baxi EcoBlue Plus Combi Quick Start Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 76
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
E
EcoBlue Plus Combi
Installation and Service Manual
Gas Fired Wall Mounted Condensing Combination Boiler
24 - 28 - 33
en
United Kingdom
These instructions include the Benchmark Commissioning Checklist
and should be left with the user for safe keeping.
They must be read in conjunction with the Flue Installation Guide.
Page view 0
1 2 3 4 5 6 ... 75 76

Summary of Contents

Page 1 - 24 - 28 - 33

EEcoBlue Plus CombiInstallation and Service ManualGas Fired Wall Mounted Condensing Combination Boiler24 - 28 - 33enUnited KingdomThese instructions i

Page 2 - Model Range

10 EcoBlue Plus Combi 7212136 - 02 (08/14)1 Introduction1.5 Extent of Liabilities1.5.1 Manufacturer's Liability Our products are manufactur

Page 3

7212136 - 02 (08/14) EcoBlue Plus Combi 11Introduction 11.5.2 Installer's ResponsibilityThe installer is responsible for the installation

Page 4 - Contents

12 EcoBlue Plus Combi 7212136 - 02 (08/14)1 Introduction1.6.2 StandardsCodes of Practice - refer to the most recent versionIn GB the following

Page 5

7212136 - 02 (08/14) EcoBlue Plus Combi 13Safety 22 Safety2.1 General Safety Instructions2.2 RecommendationsWARNING Installation, repair and maintenan

Page 6

14 EcoBlue Plus Combi 7212136 - 02 (08/14)2 Safety2.3 Specific Safety Instructions2.3.1 HandlingGeneral• The following advice should be adh

Page 7

7212136 - 02 (08/14) EcoBlue Plus Combi 15Technical Specifications 33 Technical Specifications3.1 Technical DataFlue Terminal Diameter 100

Page 8 - 1 Introduction

16 EcoBlue Plus Combi 7212136 - 02 (08/14)3 Technical Specifications0200 400 600 800 1000 12000.511.522.533.54Metre (wg)Flow Rate (l/h)Pump - Availa

Page 9 - 1.4 Abbreviations

7212136 - 02 (08/14) EcoBlue Plus Combi 17Technical Specifications 33.2 Dimensions and ConnectionsDimensionsA 700mmB 295mm C 390mm

Page 10 - 1.5 Extent of Liabilities

18 EcoBlue Plus Combi 7212136 - 02 (08/14)3 Technical Specifications3.3 Electrical DiagramLinkbg/yybrMains Input CableNELX20 X21 X30X42X41X40X60X23X22

Page 11 - 1.6 Homologations

7212136 - 02 (08/14) EcoBlue Plus Combi 19Description of the Product 44 Description of the Product4.1 General Description1. The Baxi EcoBlue Plus Comb

Page 12 - 1.6.2 Standards

2 EcoBlue Plus Combi 7212136 - 02 (08/14)You have just purchased one of our appliances and we thank you for the trust you have placed in our products.

Page 13 - 2 Safety

20 EcoBlue Plus Combi 7212136 - 02 (08/14)4 Description of the Product4.2 Operating Principle4.2.1 Central Heating Mode 1. With a demand for hea

Page 14 - 2.3.1 Handling

EV1EV1EV2EV2P. OU TP. OU T1 2 3 41 2 3 4VENTVENTRQRQADJ.ADJ.7212136 - 02 (08/14) EcoBlue Plus Combi21D

Page 15 - 3 Technical Specifications

22 EcoBlue Plus Combi 7212136 - 02 (08/14)4 Description of the Product4.4 Control Panel Description/R/P++RRRDHW and CH OFF (frost protection still ena

Page 16 - NATURAL GAS ONLY !

7212136 - 02 (08/14) EcoBlue Plus Combi 23Description of the Product 44.5 Standard Delivery1. The pack contains: Boiler Wall m

Page 17 - Dimensions

24 EcoBlue Plus Combi 7212136 - 02 (08/14)5 Before Installation5 Before Installation5.1 Installation RegulationsInstallation must be carried out in ac

Page 18 - 3.3 Electrical Diagram

7212136 - 02 (08/14) EcoBlue Plus Combi 25Before Installation 55.2 Installation Requirements5.2.1 Gas Supply 1. The gas installation should be i

Page 19 - 4 Description of the Product

26 EcoBlue Plus Combi 7212136 - 02 (08/14)5 Before Installation5.2.6 Treatment of Water Circulating Systems1. All recirculatory water systems

Page 20 - 4.2 Operating Principle

7212136 - 02 (08/14) EcoBlue Plus Combi 27Before Installation 55.2.9 Safety Pressure Relief Valve See B.S. 6798 for full details.1

Page 21 - 4.3 Main Components

28 EcoBlue Plus Combi 7212136 - 02 (08/14)5 Before Installation5.3 Choice of the Location5.3.1 Location of the Appliance 1. The boiler may be fi

Page 22 - 4.4 Control Panel Description

7212136 - 02 (08/14) EcoBlue Plus Combi 29Before Installation 55.3.5 Condensate Drain FAILURE TO INSTALL THE CONDENSATE

Page 23 - 4.6 Accessories & Options

7212136 - 02 (08/14) EcoBlue Plus Combi 3Installer Notification GuidelinesChoose BuildingRegulations NotificationRouteContact your relevant LocalAutho

Page 24 - 5 Before Installation

30 EcoBlue Plus Combi 7212136 - 02 (08/14)5 Before Installation9. If the boiler is fitted in an unheated location the entirecondensate discharge pipe

Page 25 - 5.2 Installation Requirements

7212136 - 02 (08/14) EcoBlue Plus Combi 31Before Installation 55.3.6 Clearances1. A flat vertical area is required for the installation of the

Page 26 - 5.2.7 Showers

32 EcoBlue Plus Combi 7212136 - 02 (08/14)5 Before Installation5.3.7 Flue/Chimney Location1. The following guidelines indicate the general req

Page 27

7212136 - 02 (08/14) EcoBlue Plus Combi 33Before Installation 5 Under car ports we recommend the use of the plume displacemen

Page 28 - 5.3 Choice of the Location

34 EcoBlue Plus Combi 7212136 - 02 (08/14)5 Before Installation5.3.8 Horizontal Flue/Chimney Systems1. The standard telescopic flue is suitabl

Page 29 - 50mm per metre

7212136 - 02 (08/14) EcoBlue Plus Combi 35Before Installation 55.3.9 Flue/Chimney Lengths1. The standard horizontal telescopic flue kit allows

Page 30

36 EcoBlue Plus Combi 7212136 - 02 (08/14)5 Before Installation5.5 Unpacking & Initial Preparation5.5.1 Unpacking RISK ASSESSME

Page 31 - 5.3.6 Clearances

7212136 - 02 (08/14) EcoBlue Plus Combi 37Before Installation 55.6 Connecting Diagrams5.6.1 System Filling and Pressurising 1. A filling point c

Page 32

38 EcoBlue Plus Combi 7212136 - 02 (08/14)6 Installation6 Installation6.1 General1. Remove the sealing caps from the boiler connections underthe boile

Page 33 - Property Boundary Line

7212136 - 02 (08/14) EcoBlue Plus Combi 39Installation 66.2.2 Connecting the Condensate Drain1. Remove the blanking cap, and using the elbow sup

Page 34

4 EcoBlue Plus Combi 7212136 - 02 (08/14)ContentsContents1 Introduction1.1 General1.2 Additional Documentation1.3 Symbols Used1.4 Abbreviations1.5 Ext

Page 35 - Plume Displacement Kit

40 EcoBlue Plus Combi 7212136 - 02 (08/14)6 Installation6.4 Air Supply / Flue Gas Connections6.4.1 Connecting the Flue/Chimney HORIZONTAL TELESC

Page 36 - BOTH SIDES

7212136 - 02 (08/14) EcoBlue Plus Combi 41Installation 610. Remove the flue elbow and insert the flue through the holein the wall. Fit the flue trims

Page 37 - 5.6 Connecting Diagrams

42 EcoBlue Plus Combi 7212136 - 02 (08/14)6 Installation6.5 Electrical Connections6.5.1 Electrical Connections of the appliance 1. See Section 5

Page 38 - 6 Installation

7212136 - 02 (08/14) EcoBlue Plus Combi 43Installation 6NSWEXXNorthWest1/2 H2.5m MinH45910From Relay Box123456789106.7.1 Installation of Externa

Page 39 - 6.3 Preparation

44 EcoBlue Plus Combi 7212136 - 02 (08/14)7 Commissioning7 Commissioning7.1 General1. Reference should be made to BS:EN 12828, 12831 & 14336when c

Page 40 - ‘TOP’ Label

7212136 - 02 (08/14) EcoBlue Plus Combi 45Commissioning 77.3 Commissioning Procedure7.3.1 De-Aeration Function The display backligh

Page 41

46 EcoBlue Plus Combi 7212136 - 02 (08/14)7 CommissioningSet Boiler to Maximum Rate(see 7.4.1)Allow the combustion to stabilise. Do not insert probeto

Page 42 - 6.6 Filling the Installation

7212136 - 02 (08/14) EcoBlue Plus Combi 47Commissioning 77.5 Configuring the System7.5.1 Check the Operational (Working Gas Inlet

Page 43 - 2.5m Min

48 EcoBlue Plus Combi 7212136 - 02 (08/14)7 Commissioning5. Set the central heating and hot water temperatures to therequirements of the user. Instruc

Page 44 - 7.1 General

7212136 - 02 (08/14) EcoBlue Plus Combi 49Operation 88 Operation8.1 General1. It is the responsibility of the installer to instruct the user in theday

Page 45 - 7.4 Gas Settings

7212136 - 02 (08/14) EcoBlue Plus Combi 5ContentsContents5.3.9 Flue/Chimney Lengths5.3.10 Flue/Chimney Trim5.3.11 Terminal Guard5.3.12 Flue/Chimney De

Page 46 - 7 Commissioning

50 EcoBlue Plus Combi 7212136 - 02 (08/14)8 Operation8.4 Use of the Control PanelBoiler InformationViewStandby - Reset - EscRStandby - Reset - Esc But

Page 47 - 7.6 Final Instructions

7212136 - 02 (08/14) EcoBlue Plus Combi 51Settings 99 Settings9.1 ParametersThe operating parameters of the boiler have been factory set tosuit most s

Page 48 - 7.6.2 System Draining

52 EcoBlue Plus Combi 7212136 - 02 (08/14)‘Service Due’ MessageAfter 11 months operation the ‘Service Due’ messagewill be shown on the boiler display.

Page 49 - 8 Operation

7212136 - 02 (08/14) EcoBlue Plus Combi 53Maintenance 1010.2 Standard Inspection and Maintenance Operation When performing an

Page 50

54 EcoBlue Plus Combi 7212136 - 02 (08/14)10 MaintenanceExpansion Vessel Charge - 1.0 bar13. To check the charge accurately ensure the system is cold.

Page 51 - 9 Settings

7212136 - 02 (08/14) EcoBlue Plus Combi 55Maintenance 1010.3.2 Fan (Figs. 50 & 51)1. Remove the clip securing the gas feed pipe to the air/gasve

Page 52 - After refitting the sampling

56 EcoBlue Plus Combi 7212136 - 02 (08/14)10 Maintenance10.3.4 Burner1. Undo the securing screw and remove the airbox, disengagingit from the fan ve

Page 53 - Sensing

7212136 - 02 (08/14) EcoBlue Plus Combi 57Maintenance1010.3.6 Flue Sensor1. For ease of access remove the Expansion Vessel asdescribed in Section 1

Page 54 - Changing Components

58 EcoBlue Plus Combi 7212136 - 02 (08/14)10 Maintenance10.3.11 Pump - Head Only (Fig. 57)1. Disconnect the electrical supply plug from the pump.2. C

Page 55

7212136 - 02 (08/14) EcoBlue Plus Combi 59Maintenance 1010.3.14 Safety Pressure Relief Valve (Fig. 59)1. Close the flow and return isolation taps an

Page 56 - 10.3.4 Burner

6 EcoBlue Plus Combi 7212136 - 02 (08/14)Contents10 Maintenance10.1 General & Service Message10.2 Standard Inspection & Maintenance Operation1

Page 57 - 10.3.7 Igniter (Fig. 54)

60 EcoBlue Plus Combi 7212136 - 02 (08/14)10 Maintenance10.3.16 Plate Heat Exchanger (Fig. 62 & 63)1. Close the flow & return isolation taps

Page 58

7212136 - 02 (08/14) EcoBlue Plus Combi 61Maintenance 1010.3.18 DHW Flow Regulator & Filter (Fig. 64)1. Remove the Fan & Collector (13.2). Cl

Page 59

62 EcoBlue Plus Combi 7212136 - 02 (08/14)10 Maintenance10.3.21 Main P.C.B. (Fig. 64)1. Ensure that the power to the boiler is isolated.2. Release t

Page 60 - Note offset

7212136 - 02 (08/14) EcoBlue Plus Combi 63Maintenance 1010.3.23 Expansion Vessel1. Close the flow and return isolation taps and drain the primarycirc

Page 61 - (‘Hall Effect’ Sensor)

64 EcoBlue Plus Combi 7212136 - 02 (08/14)10.3.25 Setting the Gas Valve (CO2Check) The CO2 must be only be checked and adjusted to set

Page 62

2028401091101111171181251281301331511603213847212136 - 02 (08/14) EcoBlue Plus Combi 65Troubleshooting 1111 Troubleshooting11.1 Error Codes1. If a fau

Page 63 - 10.3.24 Gas Valve (Fig. 69)

66 EcoBlue Plus Combi 7212136 - 02 (08/14)11 TroubleshootingRefer to “Illustrated Wiring Diagram” for position of terminals and componentsCentral Heat

Page 64 - Adjustment

7212136 - 02 (08/14) EcoBlue Plus Combi 6711Domestic Hot Water - Follow operational sequenceTurn on mains power The display illuminates117 or 1

Page 65 - 11.2 Fault Finding

68 EcoBlue Plus Combi 7212136 - 02 (08/14)11Fault Finding Solutions SectionsIs there 230V at:Main terminals L and N Check electrical supply1.NOMain te

Page 66 - 11 Troubleshooting

7212136 - 02 (08/14) EcoBlue Plus Combi 69Troubleshooting 11Replace PCBCheck and correct if necessary1. Ignition electrode and lead2. Electrode connec

Page 67 - Troubleshooting

7212136 - 02 (08/14) EcoBlue Plus Combi 7

Page 68

70 EcoBlue Plus Combi 7212136 - 02 (08/14)11 TroubleshootingIMTemperature sensors faulty.Cold resistance approximately10k @ 25° C (CH sensor)20k @ 2

Page 69

7212136 - 02 (08/14) EcoBlue Plus Combi 711212 Decommissioning12.1 Decommissioning Procedure1. Disconnect the gas & electric supplies and isolate

Page 70

72 EcoBlue Plus Combi 7212136 - 02 (08/14)13 Spare Parts13 Spare PartsABCDIFGKJONPMQREVSU13.1 General1. If, following the annual inspection or mainten

Page 71 - 12 Decommissioning

7212136 - 02 (08/14) EcoBlue Plus Combi 73Notes 1414 Notes

Page 72 - 13 Spare Parts

*All installations in England and Wales must be to Local Authority Building Control (LABC) either directly or through aCompetent Persons Scheme. A Bui

Page 73 - 14 Notes

www.centralheating.co.ukIt is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed

Page 74

© Baxi Heating UK Ltd 20147212136 - 02 (08/14)BAXI A Trading Division of Baxi Heating UK Ltd (3879156)Brooks House, Coventry Road, Warwick. CV34 4LLAf

Page 75 - SERVICE RECORD

8 EcoBlue Plus Combi 7212136 - 02 (08/14)1 Introduction1 Introduction1.1 General WARNING Installation, repair and main

Page 76 - Website www.baxi.co.uk

7212136 - 02 (08/14) EcoBlue Plus Combi 9Introduction 11.3 Symbols UsedIn these instructions, various levels are employed to draw theuser's atten

Comments to this Manuals