Page view 64
Comp No. 7212138 - 02 (06/14) EcoBlue Advance Combi 65
Troubleshooting 11
Refer to “Illustrated Wiring Diagram” for position of terminals and components
Central Heating - Follow operational sequence
Turn on mains power
The display illuminates
20, 28, 40 or 321
flashing
117 or 118 flashing
110, 125, 133, or 384
flashing
Set Central Heating
temperature to Maximum.
symbol flashing, pump
runs
Go to section ‘A
Go to section ‘D’
Ensure all controls and
programmers are calling
for heat
Go to section ‘B’
If 110 is still flashing
go to section ‘H’
YES
YES
NO
NO
NO
YES
YES
YES
NO
YES
YES
YES
NO
NO
Go to section ‘I’
Ensure controls are set to
demand and verify the
contacts are closed
NO
Press the reset button for 1
to 3 seconds
If 110 or 384 is flashing or re-occurs
regularly, check all PCB connections. If this
has no effect replace the PCB.
Spark at ignition electrodes
up to 5 seconds & for 4
attempts
Go to section ‘F’. Press the
reset button for 1 to 3
seconds
YES
Burner lights
Go to section ‘E’
Burner goes out after 5
seconds
133 flashing
Go to section ‘G’
YES
YES
NO
109 flashing
125 flashing after 1 min
Go to section ‘J’
YES
YES
110 or 111 flashing
NO
Go to section ‘H’
YES
NO
Diverter Valve open to
Central Heating circuit
NO
Go to section ‘K’
YES
Burner modulates to
maintain set temperature
Check Heating Flow
sensor.
Go to section ‘D’
NO
130 flashing
YES
Go to section ‘M’
YES
Burner goes out
NO
Fan stops after 15
seconds
YES
Boiler operation correct
YES
133 and flashing
Flame Displayed
YES
Check polarity
NO
NO
Fan runs at correct speed
160 flashing
Go to section ‘C’