18 EcoBlue Plus Combi
7212137 - 01 (07/14)
6 Settings
6 Settings
6.1 Setting the Boiler Temperatures
6.1.1 Boiler Temperature
To increase or decrease the boiler temperature:-
1. Press to increase the Central Heating temperature.
*
2. Press to decrease the Central Heating temperature.*
/R
/P
++
R
R
Central Heating
Temperature
Adjustment
Display Screen
Domestic Hot Water
Temperature
Adjustment
R
Summer - Winter - Heating
Only Mode
6.1.4 Information Display
1. The table opposite shows information that can be displayed
by pressing the button.
2. Depending upon boiler model and any system controls
connected to the appliance, not all information codes will be
displayed and some that are will not have a value.
3. Press to return to the normal display.
R
Button Button
R
Boiler Central Heating
Selected Temperature
Displayed*
Domestic Hot Water
Selected Temperature
Displayed
6.1.2 Domestic Hot Water Temperature
To adjust the domestic hot water temperature:-
1. Press to increase the Domestic Hot Water temperature.
2. Press to decrease the Domestic Hot Water temperature.
6.1.3 Summer - Winter - Heating Only Mode
1. Press button until the required mode appears:-
In Heating Only mode Domestic Hot Water will NOT be
supplied when a hot tap is opened.
See 6.1.1 or 6.1.2 to set the required temperature.
Summer - Domestic Hot Water only mode
Winter - Domestic Hot Water & Central
Heating mode
Heating Only - Only Central Heating mode
If and are pressed together P02 will
be displayed. Pressing either button again will scroll
through the display and P26 & P64 will be shown.
Press to return to normal display.
R
The values displayed are the temperature as measured
at the boiler, not necessarily that at the radiator or tap.
Because of differences in systems, seasonal variations
in mains water temperature etc. some adjustment of the
temperatures may be required to achieve the desired
results. Your installer will be able to offer advice.
*Where Outdoor Sensor fitted
If the control system includes an Outdoor Sensor the
temperature display and Central Heating buttons perform
different functions than those described.
Display - This shows a simulated room temperature set
point, NOT the boiler temperature.
Buttons - They will alter the displayed temperature, and
for optimum use should be used to change the displayed
temperature to the same as selected on the room
thermostat.
By selecting a temperature different to the room
thermostat altered comfort levels will be achieved. Your
installer will be able to offer advice.