10 EcoBlue Advance Combi
3 Technical Specifications
7212139 - 02 (06/14)
3 Technical Specifications
3.1 Technical Data
Central Heating Primary Circuit
Pressures
bar
Safety Discharge 3
Max Operating 2.5
Min Operating 0.5
Recommended Operating Range 1-2
DHW Circuit bar
Pressures
Max Operating 8
Min Operating 0.15
Flow Rates (24) (28) (33) (40)
l/min l/min l/min l/min
DHW Flow Rate
@ 35
o
C Rise 9.8 11.5 13.5 16.4
Min Working
DHW Flow Rate 2 2 2 2
Temperatures
C.H. Flow Temp (adjustable)
25°C to 80°C max (± 5°C)
D.H.W. Flow Temp (adjustable)
40°C to 60°C max (± 5°C)
dependent upon flow rate
Electrical Supply 230V~ 50Hz
(Appliance must be connected to an
earthed supply)
External Fuse Rating 3A
NOTE: All data in this section are nominal
values and subject to normal production
tolerances.
IMPORTANT: Where Low Flow Taps or Fittings
are intended to be used in the DHW system
connected it is strongly recommended that the
DHW flow rate DOES NOT fall below 2.5 l/min.
This will ensure reliable operation of the DHW
function.
150mm* Min
763mm
450mm
175 mm Min (300mm
Min if using 80/125mm
flueing system)
5mm Min
5mm Min In
Operation
450mm Min
5mm Min
345mm
For Servicing
Purposes &
Operating the
Controls
*This is MINIMUM
recommended dimension.
Greater clearance will aid
installation and maintenance.
Electrical Protection
IPX5D (without integral timer)
IP20 (with integral timer)
Dimensions & Clearances These must be maintained in the event of